different specimens show the influence of notching and surface quality
Code | WP140 |
Description:
- Moving components and machine parts are often exposed to periodically fluctuating loads.
- Even if the dynamic load is far below the static load capacity, this load can lead to fracture of the component after a long time because of material fatigue.
- The fatigue strength and design strength of components are determined in fatigue strength tests or endurance tests.
- The WP 140trainer demonstrates the basic principles of fatigue strength testing and the creation of a Wöhler diagram.
- The clean layout and simple operation mean the experimental sequence can be observed in all details and phases.
- In the experiment, a cantilever-mounted and rotating cylindrical specimen is subjected to a single force.
- The load on the specimen corresponds to a cantilever bending beam.
- The specimen is subjected to a pure reverse bending stress and breaks after a certain number of load cycles because of material fatigue.
- The necessary force is generated in the load application device by means of a spring balance and a movable support.
- The load amplitude can be adjusted continuously using the preload of the spring balance by means of a threaded spindle.
- An electronic counter registers the number of load cycles and displays it digitally.
- The impulse for the counter is provided by an inductive proximity switch on the motor coupling. The counter can also be used to measure the speed.
- When the specimen breaks, the stop switch stops the electric motor automatically.
- A protective cover protects against flying fragments.
- Specimens with various fillet radii are included in the scope of delivery to demonstrate the notching effect and the influence of the surfaces.
- By using the WP 140.20system for data acquisition, the measured values can be transferred to a PC where they can by analysed with the software.
Technical Details:
Specifications:
- basic principles of fatigue strength testing
- driven by electric motor
- automatically shuts down when the specimen fractures
- load application device with sliding movable support, threaded spindle with hand wheel, spring balance
- steel cylindrical specimens, various fillet radii
- speed measured by contactless inductive speed sensor or electronic counter for load cycles
- digital counter display
- protective cover for safe operation
- system for data acquisition (WP 140.20) available as an option
Technical Data:
- Electric motor:
- speed: 2800min-1
- power: 0,37kW
- Load force:
- 0…300N
- Electronic load counter:
- 8-digit
- switchable to indicate speed
- Specimens:
- material: steel
- 3 different fillet radii
- 230V, 50Hz, 1 phase
- 230V, 60Hz, 1 phase; 120V, 60Hz, 1 phase
- UL/CSA optional
Dimensions & Weight:
- L x W x H: 840x410x600mm
- Weight: approx. 31kg
Learning Objectives/Experiments:
- fatigue strength of bars under reverse bending stress
- influence of different fillet radii and surface qualities on the fatigue strength
- Wöhler diagram
Scope of Delivery:
- 1 experimental unit
- 1 set of specimens (9 pieces)
- 1 set of instructional material
Features:
- continuous adjustment of the load amplitude
- automatically shuts down when the specimen fractures
Accessories:
- Optional:
- WP 140.01Set of 3 specimens, various fillet radii, St
- WP 140.20System for data acquisition
- WP 300.09Laboratory trolley
Due to the continuous development of our products, the goods supplied may vary in detail to that illustrated on this Website.