Distance Pieces and Pedestal (UTC-4630)

Distance Pieces and Pedestal (UTC-4630)

Compression Testing Frames

Code UTC-4630

Product Code:

UTC-4630 Distance Pieces, Ø 165×15 mm (Ø6,5”x0,59”)
UTC-4631 Distance Pieces, Ø 165×30 mm (Ø6,5”x1,18”)
UTC-4633 Distance Pieces, Ø 165×50 mm (Ø6,5”x1,97”)
UTC-4634 Distance Pieces, Ø 165×100 mm (Ø6,5”x3,93”)
UTC-4636 Distance Pieces, Ø 205×30 mm (Ø8,07”x1,18”)
UTC-4638 Distance Pieces, Ø 205×50 mm (Ø8,07”x1,97”)
UTC-4639 Distance Pieces, Ø 205×100 mm (Ø8,07”x3,93”)
UTC-4680 Pedestal for 600 kN (135000 lbf), 1100 kN (245000 lbf) Compression Testing Frames
UTC-4682 Pedestal for 1500 kN (335000 lbf), 2000 kN (450000 lbf) and 3000 kN (670000 lbf) Compression Testing Frames
UTC-4684 Pedestal for Four Column 2000 kN (45000 lbf) and 3000 kN (670000 lbf) Compression Testing Frames
UTC-4686 Pedestal for Four Column 4000 kN (900000 lbf) and 5000 kN (1250000 lbf) Compression Testing Frames

Description:

  • Distance pieces are used to reduce the amount of vertical clearance between the upper platen and the lower platen.
  • For lowering the minimum distance between upper and lower platens down to required height, 2000 kN, 3000 kN and 4000 kN machines are supplied with 205 mm (8,07”) dia. distance pieces and 600 kN, 1100kN and 1500 kN machines are supplied with 165 mm (6,5”) dia. distance pieces.
  • Distance pieces are equipped with handles.

Product Code

Dimensions

Weight (approx.)

UTC-4630

165x165x15mm 2,5 kg (5,5 lbs)
UTC-4631 165x165x30 mm

5 kg (11 lbs)

UTC-4633

165x165x50 mm 8 kg (17,6 lbs)

UTC-4634

165x165x100 mm

15,5 kg (34,2 lbs)

UTC-4636 205x205x30 mm

8 kg (17,6 lbs)

UTC-4638

205x205x50 mm 13 kg (28,7 lbs)
UTC-4639 205x205x100 mm

24,5 kg (54,0 lbs)

UTC-4680

545x540x545 mm 50 kg (110 lbs)
UTC-4682 725x540x445 mm

55 kg (122 lbs)

UTC-4684

775x580x445 mm

84 kg (186lbs)

UTC-4686 785x580x445 mm

90 kg (199 lbs)

LOADING CYLINDER ASSEMBLY:

  • All frames have a single acting up stroking ram.
  • The diameter of the piston is designed to work with the load capacity.
  • The maximum ram movement is 50 mm.
  • The pressure transducer is used for load measurements.
  • There is a low friction coaxial PTFE seal between the cylinder and the piston fitted to the cylinder.

PEDESTAL FOR FRAMES:

  • The pedestals make it easier for the user to placement of specimens in the frames for compression test.

 

Due to the continuous development of our products, the goods supplied may vary in detail to that illustrated on this Website.